AMI - Advanced Metering Infrastructure

Since September, 2017

304 followers »
AMI - Advanced Metering Infrastructure
URL:https://Eaton.workoutloud.com/Group/ami-advanced-metering-infrastructure-

About

Group for all Eaton AMI customers

More Details

Owners

Darlene Oleksik
Megan Freeman
William Arnlund

Followers304

Agyeman Stephen Opoku
Alayande Akintunde
Alix Dustin
Allen Kevin
Anderson Steven
Annan Albert
Anthofer Josh
Apeña Reyes Maximo
Arden Daniel

Tagged

AMI
advanced metering
smart grid network
smart metering
Fri, August, 12th 2022

Delivered Read
Fri, April, 29th 2022

Product Advisory regarding RFN-410cL, RFN-420cL, and RFN-420cD deliveries.
RFN-410cL, RFN-420cL, RFN-420cD Endpoint Deliveries_04-29-2022.pdf
Delivered Read
Fri, March, 11th 2022

Forum Question/Topic:

Article:

Yukon/NM v9.1 and RF Mesh Firmware v9.5 release notes

Categorized as:

Please see the attached release notes for in-depth detail on the latest software and firmware features, improvements, and fixes.
Yukon9.1ReleaseNotes.pdf
AMI
Yukon
software
Meter
Delivered Read

Forum Question/Topic:

Article:

Yukon/NM v9.1 and RF Mesh Firmware v9.5 are available for upgrades!

Categorized as:

Yukon v9.1.3 and Network Manager v9.1.1 are the latest available software releases. Some of the new AMI features included in v9.1 include:
- Ability to receive GPS coordinates from the Gateway 800/801 after programmed on-site with Network Runner
- New data channels for Elster A3, Landis+Gyr S4x/S4e/FOCUS RX(e), and Itron SENTINEL
- Ability to detect meter model changes in the field and update accordingly
- Addition of new device types for FOCUS AXe  Read more...meters to differentiate them from AX meters
- Tracking of meter firmware versions (in addition to RFN version)
- General improvements around mapping, smart notifications, data collection, and the RFN-1200

Also, RF Mesh Firmware v9.5 has just recently been released for general availability after several months of early monitoring and evaluation. New features and improvements here include:
- Gateway improvements to help prevent reaching the 5,000 node limit
- Extended water node support for new meters and protocols
- FOCUS meter optical port is now available for 5 minutes after power-up for probe access without requiring use of Network Runner
- Increased the maximum number of battery nodes that can associate to a relay
- Prevention of false gateway alarms on UPS battery voltage low when a UPS is not connected
- Improved network link adaptation algorithms to optimize routing
- New data channels for Elster A3, Landis+Gyr S4x/S4e/FOCUS RX(e), and Itron SENTINEL
- Network Runner improvements including addition of RSSI signal measurements, new commands to shed LCRs longer, and ability to export on-demand readings in decimal format

Please check out the Yukon 9.1 What's New guide here and Yukon 9.1 Release Notes that will be uploaded shortly for more details on these and other changes included in the latest software and firmware releases. Show less...
Yukon9.1WhatsNew.pdf
AMI
Yukon
software
Meter
Delivered Read
Brad Lingen likes this.
Thu, March, 10th 2022

1

Forum Question/Topic:

Article:

Single Phase Meter Resets on its own

Categorized as:

We are having issues with our Itron C2SX and C1SX meters resetting to zero after reaching the value 4294967295 which is FFFFFFFF in hex. In network manager and Yukon the value resets to zero once this value is passed but the display keeps accumulating. Has anyone else had this issue?
AMI
Meter
software
Yukon
Delivered Read
1
Hey Zach! Yes, this issue is present in all firmware versions prior to v9.3.4 and v9.4 and is also true for L+G residential meter types (resolved in v9.4+ only for L+G nodes). A firmware upgrade will prevent this from occurring for you in the future and can hopefully help others who see your post here as well.
Wed, February, 23rd 2022

Please see the attached notice regarding the RFN-510fL and MCT-410fL products which utilize the Landis+Gyr FOCUS AL meter.
RFN-510fL MCT-410fL Endpoint - Landis+Gyr FOCUS AL EOL Notification.pdf
Delivered Read
Phil Stern likes this.
Thu, May, 20th 2021

Forum Question/Topic:

Article:

Yukon/NM v9.0 and RF Mesh Firmware v9.4 Release Notes

Categorized as:

You can find all the latest Yukon, Network Manager, RF Mesh Firmware, and Network Runner feature additions, changes, and bug fixes in the attached release notes. A must read for all AMI power users!
Yukon9.0ReleaseNotes.pdf
AMI
Meter
software
Yukon
Delivered Read
Stacey Nelson likes this.

Forum Question/Topic:

Article:

Yukon/NM v9.0 and RF Mesh Firmware v9.4 now available!

Categorized as:

Five new AMI features in this release include:

- Added CMEP flexibility in Yukon's Data Export tool for cleaner third party MDMS integrations, especially for NISC
- New RF Mesh Gateway alarms, infrastructure warnings, and Yukon management tools
- Added support for additional meter data channels
- New ability to disable/reenable the Advanced Metrology Preferred setting for L+G FOCUS AX meter types, especially to allow reading the meter's TOU and demand values  Read more...rather than values from the AMI module's Advanced Metrology
- Faster meter blink detection, down to 1/2 second for some meters

And there are many more to check out in the attached Yukon What's New guide. Please contact our deployment and support teams to schedule your upgrade. Show less...
Yukon9.0WhatsNew.pdf
AMI
Yukon
software
Meter
Delivered Read
Stacey Nelson likes this.
Tue, September, 1st 2020

Guess what!?!?

2 sessions added on Friday – IED Management Suite User Group and SMP User Group!

Join us for the now 8-part Users Training Monday, September 14 -Friday, September 18th that will take place online. It has almost everything (besides meeting everyone in person!) our attendees have loved in the past: new features demonstrations, open-forum user request discussion and utility use-case technical presentations. Did we also say it is completely FREE for EAS  Read more...users?

Register under the events tab to take part in this online event and connect with the EAS community! Each of the 8 presentations requires separate registration. The webinar link will be emailed separately the morning of each presentation and only to those who have registered for that specific presentation.  Show less...
Delivered Read
Tue, August, 25th 2020

Reminder! The Eaton EAS User Training registration is now live!!!
Join us for the 6-part Users Training September 14 -17th that will take place online. It has almost everything (besides meeting everyone in person!) our attendees have loved in the past: new features demonstrations, open-forum user request discussion and utility use-case technical presentations. Did we also say it is completely FREE for EAS users? Sign up today under the Events tab to take part in this online event and  Read more...connect with the EAS community next month! Each of the 6 presentations requires separate registration. The webinar link will be email separately the morning of each presentation and only to those who have registered for that specific presentation.
Contact Megan Freeman at meganfreeman@eaton.com with questions. Show less...
Delivered Read
Tue, August, 18th 2020

The Eaton EAS User Training registration is now live!!!
Join us for the 6-part Users Training September 14 -17th that will take place online. It has almost everything (besides meeting everyone in person!) our attendees have loved in the past: new features demonstrations, open-forum user request discussion and utility use-case technical presentations. Did we also say it is completely FREE for EAS users? Sign up today under the Events tab to take part in this online event and connect with  Read more...the EAS community next month! Each of the 6 presentations requires separate registration. The webinar link will be email separately the morning of each presentation and only to those who have registered for that specific presentation.
Contact Megan Freeman at meganfreeman@eaton.com with questions.  Show less...
Delivered Read
Thu, November, 7th 2019

Forum Question/Topic:

Article:

RF Mesh firmware 9.1 and Yukon 7.3 are now available!

Categorized as:

Consider upgrading your network firmware and Yukon software versions to take advantage of our latest features and improvements. As a reminder, these upgrades are included at no additional cost with your annual maintenance package!

Here are just a few of the new features in Yukon v7.3, FW v9.1, and FW v9.0 (included here due to its limited installations). Many of the listed FW features are combined engineering efforts with Yukon and require the correct Yukon versions as well, so  Read more...we recommend upgrading all the way to Yukon v7.3 before the upgrade to FW v9.1.

Yukon 7.3
• Comprehensive mapping showing nodes by primary gateway or link quality
• Option for the CIS to update device GPS coordinates via MultiSpeak
• Battery Node Analysis Report to identify end-of-life batteries
• Demand response using disconnect meters for a single device to both meter and control sub-metered loads

RF Mesh Firmware 9.1
• Advanced Tamper Detection
• Badger Water Events
• Support of Yukon Device Configuration improvements for polyphase meters
• Meter disconnect status is now provided in the initial data report to help ensure data synchronization
• Additional metrics supported for polyphase meters

RF Mesh Firmware 9.0
• IPv6 support across the RF Mesh down to end nodes
• Anycast and other significant outage improvements for much higher last gasp and restoration alarm success rates (ask about our new recommended timing settings for outage/restoration alarms)
• Improved reliability of clearing outage and OV/UV events appropriately
• Additional metrics supported for polyphase meters
• Yukon Device Configuration scalability improvements allow configuration of larger numbers of meters at once
• Yukon Device Configuration support to change the Demand Interval in single phase meters using Eaton's Advanced Metrology
• Wired gas node support and the RFG-201 Yukon device type

The latest firmware release has been closely monitored in limited deployments over the last three months and is ready for your upgrade. Contact our Technical Services team today to learn more and plan your upgrades! Show less...
AMI
Yukon
Delivered Read
Eric Lopez(WOL), Eve Richardson, William Arnlund, Brad Lingen like this.
Thu, November, 8th 2018

[Uploaded File]

Dan has uploaded files to: AMI - Advanced Metering Infrastructure

See these files and others at: https://Eaton.workoutloud.com/Group/ami-advanced-metering-infrastructure-/Files
2 Eaton RF Mesh 101 - 2018 Final.pdf
1 Eaton AMI 101 - 2018 Final.pdf
3 Eaton Smart Grid Solutions Overview - 2018 Final.pdf
6 Field Troubleshooting - 2018 Final.pdf
5 RF Mesh Deployment - 2018 Final.pdf
7 Fiber To Home Considerations - 2018 Final.pdf
8 New Field Tool - 2018 Final.pdf
9 RF Installation - Owen Electric Practices - 2018 Final.pdf
10 Hosted Yukon - PCS - 2018 Final.pdf
11 Consumer Portal - MyMeter - 2018 Final.pdf
12 Remote Access Best Practices - 2018 Final.pdf
Delivered Read
Warren McKenna likes this.
Wed, March, 14th 2018

Forum Question/Topic:

Article:

NE Regional AMI & DR Users' Group - Sign up Today!

Categorized as:

Allegheny Electric Cooperative is putting on their annual NE Regional Users' Group May 9-10, hosted this year by REA Energy Cooperative at their office in Indiana, PA, East of Pittsburgh. Several Allegheny members will be in attendance as well as Eaton personnel and there is still room to accommodate about 10 more if you're interested! There will be plenty of time for discussion, Q&A, and connecting with AMI/DR system operators from other utilities, with a (draft) agenda to include:
 Read more...
May 9th 2018 - Wednesday
1:00- 1:10 Welcome & Introductions – Chris Masterson, Tony Vincik
1:10 – 1:30 Systems Deployment Update – Tony Vincik
1:30 – 2:00 RF Updates – REA, Somerset, Bedford
2:00 – 2:45
2:45 – 3:00 Break
3:00 – 4:00 Round Table

May 10th 2018 - Thursday
8:00 – 8:45 Eaton Issues/Q&A
a. Lead Times
b. PLC Support/Future
c. Etc…
8:45 – 9:30 Yukon – New Features/Releases/Product updates - Eaton
9:30 – 10:00
10:00 – 10:30 Break
10:30 – 11:15 RF Discussion
11:15 – 12:00 Round Table
12:00 - Lunch (Provided)

Please post here or contact me directly if you're interested in attending and we can provide more details.

Also, if anyone is interested in attending meetings closer to home or hosting their own regional meeting you can use the forum here to gauge other interest or contact us to see what might be happening in your area this year. Show less...
AMI
load management
Yukon
Delivered Read
Eve Richardson likes this.
Tue, February, 13th 2018

What topics would you like to see discussed at this year's User Training and Technical Showcase?
Delivered Read